Representative Image

Edmund Bühler Bühler High-Temperature Option (up to 60 °C) for TH 15 and TH 30 Shakers

Specifications

HS Code #
84199085
Description
High temperature option (to 60 °C)
Fits for
TH 15/TH 30
UNSPSC
40101800

SG $587.40

Inc. GST

Available soon

Product description

The Edmund Bühler Bühler High-Temperature Option is an accessory designed to enhance the temperature capabilities of the TH 15 and TH 30 shakers. This option allows the shakers to operate at temperatures up to 60 °C, expanding their application range to include processes that require elevated temperatures, such as certain chemical reactions, incubations, and sample preparations.

Key Features:

  • Brand: Edmund Bühler Bühler
  • Compatibility: Specifically designed for use with TH 15 and TH 30 shakers
  • Temperature Range: Enables operation at temperatures up to 60 °C
  • Application: Ideal for laboratory processes requiring controlled elevated temperatures, including chemical reactions, incubations, and sample preparations
  • Enhancement: Expands the functionality of existing TH 15 and TH 30 shakers, providing greater versatility in laboratory applications

This high-temperature option is essential for laboratories looking to extend the capabilities of their TH 15 and TH 30 shakers to accommodate a broader range of experimental protocols.

Frequently asked questions

It is an accessory designed to enhance the temperature capabilities of the TH 15 and TH 30 shakers. This option allows the shakers to operate at temperatures up to 60 °C, expanding their application range to include processes that require elevated temperatures, such as certain chemical reactions, incubations, and sample preparations.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story
Edmund Bühler Bühler High-Temperature Option (up to 60 °C) for TH 15 and TH 30 Shakers | LabFriend Singapore