Representative Image

Thermo Orion Ammonia High-Performance Electrode, with Waterproof BNC Connector

Specifications

Cable length
1 m
Connection plug
BNC
Shaft length
120 mm
Material shaft
Epoxy
Max. temperature
50 °C
Min. temperature
0 °C
Shaft Ø
12 mm
Temperature
0 ... 50 °C
UNSPSC
41115608

SG $1,777.03

Inc. GST

Available soon

Product description

The Thermo Orion Ammonia High-Performance Electrode is designed for precise ammonia measurements in both drinking water and wastewater applications. Ideal for high-performance applications, this electrode delivers rapid results within one minute for concentrations from 1 ppm and higher. It offers a very good linear response, especially at lower levels, ensuring accurate and reliable measurements. Its waterproof BNC connector makes it compatible with any pH meter equipped with a BNC input and concentration mode.

Key Features:

  • Brand: Thermo Orion
  • Model: 9512HPBNWP
  • Type: Combination Ammonia Ion Selective Electrode
  • Connector: Waterproof BNC
  • Cable Length: 1 meter
  • Operating Temperature Range: 0°C to 50°C (32°F to 122°F)
  • Electrode Body Material: Epoxy with a translucent design for easy monitoring of fill solution levels
  • Dimensions: Length: 120 mm; Diameter: 12 mm
  • Concentration Range: 0.01 to 17,000 ppm as NH3 (5 x 10⁻⁷ M to 1 M)
  • Response Time: Approximately 1 minute in samples with concentrations of 1 ppm and higher
  • Compliance: Meets EPA testing methods for ammonia measurement

Scope of Supply:

  • Waterproof BNC connector
  • 1 m cable
  • 20 loose membranes (Catalog No. 951214)
  • One pre-assembled outer body with membrane cap (Catalog No. 951215)
  • Two 60 mL bottles of electrode filling solution (Catalog No. 951209)
  • Spout cap and tweezers

Enhance your ammonia analysis with the Thermo Orion Ammonia High-Performance Electrode, offering durability, ease of maintenance, and precise measurements for demanding applications.



Frequently Asked Questions

1. What is the Thermo Orion Ammonia High-Performance Electrode, with Waterproof BNC Connector used for?

It is designed for precise ammonia measurements in both drinking water and wastewater applications. Ideal for high-performance applications, this electrode delivers rapid results within one minute for concentrations from 1 ppm and higher. It offers a very good linear response, especially at lower levels, ensuring accurate and reliable measurements. Its waterproof BNC connector makes it compatible with any pH meter equipped with a BNC input and concentration mode.

2. Is this product suitable for precise ammonia measurements in both drinking water and wastewater applications?

Yes. It is designed for precise ammonia measurements in both drinking water and wastewater applications, and offers a cable length of 1 meter and an operating temperature range of 0°C to 50°C (32°F to 122°F) to support this kind of work.

3. What cable length and operating temperature range does this product have?

It has a cable length of 1 meter, an operating temperature range of 0°C to 50°C (32°F to 122°F) and a concentration range of 0.01 to 17,000 ppm as NH3 (5 x 10⁻⁷ M to 1 M).

4. What type and connector does this product offer?

It offers combination Ammonia Ion Selective Electrode, waterproof BNC, epoxy with a translucent design for easy monitoring of fill solution levels and length: 120 mm; Diameter: 12 mm.

Downloads

Accessories

Calibration standards for ammonia ISE electrodes

ProductContainer typeIntake capacityMfr#Part#AvailabilityPrice
Bottle100 ppm9512076.258 451SG $233.48
Bottle0.1 M9510066.258 453SG $270.54

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

SG $1,777.03

Inc. GST