Representative Image

Ludwig Schneider Sensor Type K for Immersion (NICR-NI) with Miniature Connector Yellow, Nominal Length 250 mm Sheath ø 0.5 mm, Application Range -100...+400°C

Ø

Dimensions (ØxL)

Length

Max. temperature

Min. temperature

Temperature

Specifications

Compare models
Cable length
2 m
Ø
0.5 mm
Dimensions (ØxL)
0.5 x 250 mm
Length
250 mm
Max. temperature
400 °C
Min. temperature
-100 °C
Sort of probe
Immersion probe
Temperature
-100 ... 400 °C
Type of probe
Type K
UNSPSC
41112219

SG $353.92

Inc. GST

Available soon

Product description

The Ludwig Sensor Type K For Immersion (NICR-NI), With Miniature Connector Yellow, Nominal Length 250mm, Sheath Diameter 0.5mm, Application Range -100 To +400°C is designed for precise immersion temperature measurement in laboratory and technical applications. This mineral-insulated thermocouple uses 1 x NiCr-Ni Type K construction and includes a yellow miniature connector for dependable temperature monitoring.

Key Features:

  • Brand: Ludwig
  • Sensor Type: Type K thermocouple for immersion
  • Material: 1 x NiCr-Ni Type K
  • Connector: Yellow miniature connector
  • Nominal Length: 250mm
  • Sheath Diameter: 0.5mm
  • Application Range: -100 to +400°C
  • Compliance: DIN EN 60584 Class 1

This Ludwig Type K immersion sensor is suitable for users requiring a fine 0.5mm sheath thermocouple for accurate temperature measurement across a broad application range.

Compare similar models

Sensor type K for immersion (NICR-NI) w/ miniature connector yellow,nominal length 250mm sheath ø 0,5 mm, application range -100...+400°C

Manufacturer P/N

71117

Part Number

6.313 330

Manufacturer

Ludwig Schneider

Ø

0.5 mm

Sensor type K for immersion (NICR-NI) w/ miniature connector yellow,nominal length 150mm sheath ø 3 mm, application range -50...+200°C

Manufacturer P/N

71110

Part Number

6.313 338

Manufacturer

Ludwig Schneider

Ø

3 mm

Sensor type K for immersion (NICR-NI) w/ miniature connector yellow,nominal length 250mm sheath ø 1 mm, application range -100...+400°C

Manufacturer P/N

71114

Part Number

6.313 334

Manufacturer

Ludwig Schneider

Ø

1 mm

Mineral-insulated thermocouple NiCri-Ni type K,-200...+800°C, acc.to DIN EN 60584, cl.1

Manufacturer P/N

57499

Part Number

9.236 709

Manufacturer

Ludwig Schneider

Ø

3 mm

Sensor type K for immersion (NICR-NI) w/ miniature connector yellow,nominal length 600mm sheath ø 3 mm, application range -100...+1000°C

Manufacturer P/N

71112

Part Number

6.313 336

Manufacturer

Ludwig Schneider

Ø

3 mm

Sensor type K for immersion (NICR-NI) w/ miniature connector yellow,nominal length 400mm sheath ø 0,5 mm, application range -100...+800°C

Manufacturer P/N

71118

Part Number

6.313 329

Manufacturer

Ludwig Schneider

Ø

0.5 mm

Sensor type K for immersion (NICR-NI) w/ miniature connector yellow,nominal length 150mm sheath ø 1 mm, application range -50...+200°C

Manufacturer P/N

71113

Part Number

6.313 335

Manufacturer

Ludwig Schneider

Ø

1 mm

Sensor type K for immersion (NICR-NI) w/ miniature connector yellow,nominal length 400mm sheath ø 1 mm, application range -100...+800°C

Manufacturer P/N

71115

Part Number

6.313 333

Manufacturer

Ludwig Schneider

Ø

1 mm

Sensor type K for immersion (NICR-NI) w/ miniature connector yellow,nominal length 150mm sheath ø 0,5 mm, application range -50...+200°C

Manufacturer P/N

71116

Part Number

6.313 332

Manufacturer

Ludwig Schneider

Ø

0.5 mm

Frequently asked questions

The Ludwig Sensor Type K For Immersion (NICR-NI), With is designed for precise immersion temperature measurement in laboratory and technical applications. The stated format and features make the product suitable for routine laboratory work within that application.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

SG $353.92

Inc. GST