Representative Image

Mettler Toledo pH Electrode InLab Routine Body, Length 120 mm

Connection plug

Temperature sensor

Type

Specifications

Compare models
HS Code #
90278930
Connection plug
S7 plug head
Diaphragm
Ceramic
Electrolyte
KCl 3 mol/l
Shaft length
120 mm
Material shaft
Glass
Max. pH value
14
Max. temperature
100 °C
Min. pH value
0
Min. temperature
0 °C
pH range
0 ... 14

SG $500.31

Inc. GST

Supplier Stock: 13
Estimated shipping time from Germany : 4-6 weeks

Product description

The Mettler-Toledo pH Electrode InLab Routine is a high-precision combination electrode designed for routine pH measurements in laboratory applications. With a body length of 120 mm, it is versatile and compatible with various pH meters. The high-quality glass membrane ensures accurate readings, while the robust construction guarantees durability in diverse testing environments. Its ceramic junction and ARGENTHAL™ reference system enhance stability and extend the electrode’s lifespan, making it ideal for consistent and reliable pH measurement.

Key Features:

  • Brand: Mettler-Toledo
  • Type: Combination pH electrode
  • Body Length: 120 mm for versatile applications
  • Membrane Glass: High-quality glass for precise pH measurement
  • Junction: Ceramic junction for enhanced stability
  • Reference System: ARGENTHAL™ with Ag+-trap for longer lifespan
  • pH Range: 0 to 14 for broad testing capabilities
  • Temperature Range: 0°C to 100°C for laboratory versatility
  • Application: Ideal for routine laboratory pH measurements

Note: please order separately.

The Mettler-Toledo InLab Routine pH Electrode is essential for laboratories that require accurate, reliable, and long-lasting pH measurement solutions.

Accessories

Connection cables for electrodes with S7 plug head

ProductLengthConnection plugMfr#Part#AvailabilityPrice
1.2 mBNC302819159.041 613In stockSG $211.24
1.2 mDIN302819199.041 634In stockSG $235.33
1.2 m2 mm banana302819239.041 662SG $233.48
1.2 m4 mm banana302819229.041 661SG $233.48
5.0 m302819279.041 669SG $313.16
1.2 mLemo302819259.041 664SG $344.66
1.2 mBNC, watertight302819189.041 656SG $233.48
10.0 m302819289.041 670SG $337.25
3.0 m302819269.041 668SG $218.65
5.0 mBNC302819179.041 654SG $313.16
3.0 mBNC302819169.041 636SG $246.45
3.0 mDIN302819209.041 657SG $276.10
5.0 mDIN302819219.041 658SG $365.04
1.2 mRCA302819249.041 663SG $227.92

Compare similar models

pH electrode InLab® Routine body length: 120 mm

Manufacturer P/N

51343050

Part Number

9.041 450

Manufacturer

Mettler-Toledo

Connection plug

S7 plug head

pH-Electrode InLab® Routine Pro-ISM pH 0...14, bole length 120mm, MultiPin plug head

Manufacturer P/N

51344055

Part Number

7.629 195

Manufacturer

Mettler-Toledo

Connection plug

MultiPinTM plug head

pH electrode InLab® Routine Pro body length: 120 mm

Manufacturer P/N

51343054

Part Number

9.041 454

Manufacturer

Mettler-Toledo

Connection plug

MultiPinTM plug head

pH electrode InLab® Routine PT1000 body length: 120 mm

Manufacturer P/N

51343056

Part Number

9.041 456

Manufacturer

Mettler-Toledo

Connection plug

MultiPinTM plug head

pH Electrode InLab® Routine Go-ISM

Manufacturer P/N

30248832

Part Number

6.284 124

Manufacturer

Mettler-Toledo

Connection plug

BNC/RCA

Frequently asked questions

The Combination pH electrode is designed for routine laboratory pH measurements. This combination ph electrode format supports routine laboratory work in that application.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story