Product description

The SCAT SafetyCap IV, V2.0, GL45 is designed to provide secure and efficient solvent handling in laboratory environments. This cap features four PFA fittings (1.6/2.3/3.2 mm OD), an integrated air valve for pressure equalization, and a labeling field for easy identification. Constructed from durable PTFE, it ensures chemical resistance and compatibility with various solvents. Ideal for use with HPLC systems, it offers enhanced safety and convenience for laboratory operations.

Key Features:

  • Brand: SCAT
  • Thread Size: GL45
  • Material: PTFE for chemical resistance
  • Fittings: 4 x PFA fittings (1.6/2.3/3.2 mm OD)
  • Air Valve: Integrated for pressure equalization
  • Labeling Field: Yes, for easy identification
  • Application: Suitable for HPLC systems and solvent handling

Scope of Supply:

  • Safety Cap
  • Shut-off
  • Air valve
  • Change indicator
  • PFA fittings
  • PFA blind plug
  • Labelling field

The SCAT SafetyCap IV, V2.0, GL45 combines advanced safety features and reliable performance, making it an essential component for laboratories seeking efficient solvent handling solutions with minimal risk of contamination or vapor loss.



Frequently Asked Questions

1. What is the SCAT SafetyCap IV, V2.0, GL45 used for?

It is designed to provide secure and efficient solvent handling in laboratory environments. This cap features four PFA fittings (1.6/2.3/3.2 mm OD), an integrated air valve for pressure equalization, and a labeling field for easy identification. Constructed from durable PTFE, it ensures chemical resistance and compatibility with various solvents. Ideal for use with HPLC systems, it offers enhanced safety and convenience for laboratory operations.

2. Is this product suitable for HPLC systems and solvent handling?

Yes. It is designed for HPLC systems and solvent handling, and offers 4 x PFA fittings (1.6/2.3/3.2 mm OD) to support this kind of work.

3. What fittings does this product have?

It has 4 x PFA fittings (1.6/2.3/3.2 mm OD).

4. What is this product made from and what features does it include?

It is made from PTFE for chemical resistance. It also offers GL45, integrated for pressure equalization and yes, for easy identification.

Accessories

Thread adapters for SafetyCaps / SafetyWasteCaps, female / male thread

ProductMaterialColourMfr#Part#AvailabilityPrice
PPColourless1070994.005 483In stockSG $198.27
PTFEWhite1079929.139 882SG $201.98
PTFEWhite1079919.139 883SG $201.98
PTFEWhite1079934.005 639SG $201.98
PPColourless1079954.005 641SG $198.27
PPColourless1079964.005 642SG $198.27
PPColourless1079944.005 640SG $198.27
PPColourless1070934.005 477SG $198.27
PPColourless1070794.005 463SG $279.80
PPColourless1070904.005 474SG $198.27
PPColourless1070284.005 433SG $198.27
PTFEWhite1170304.005 789SG $201.98
PPColourless1070954.005 479SG $198.27
PPColourless1070924.005 476SG $198.27
PTFEWhite1070724.005 456SG $279.80
PPColourless1070944.005 478SG $118.59
PPColourless1070864.005 470SG $198.27
PPColourless1070974.005 481SG $201.98
PPColourless1070744.005 458SG $218.65
PPColourless1070854.005 469SG $198.27
PPColourless1070894.005 473SG $198.27
PPColourless1070914.005 475SG $157.50
PPColourless1070964.005 480SG $198.27
PPColourless1070714.005 950SG $198.27
PPColourless1070844.005 468SG $201.98

Air valves Generation 2.0 for SafetyCaps

ProductColourShelf lifeMfr#Part#AvailabilityPrice
Red6 months3170104.669 375In stockSG $100.06
Red6 months3970504.669 377In stockSG $2,318.10
Red6 months3970104.669 376In stockSG $537.37
Red6 months3970086.318 227In stockSG $453.98
Red6 months3971004.683 899SG $3,246.46

Compare similar models

SafetyCap IV, V2.0, GL45
Available soon
SCAT SafetyCap IV, V2.0, GL45

SG $357.63

Inc. GST

Manufacturer P/N

307419

Part Number

4.680 965

Manufacturer

SCAT

Capillary connections

4

SafetyCap III, V2.0, GL45 with 3x shut-off, 3x PFA-fitting 3,2 mm OD + air valve

Manufacturer P/N

307920

Part Number

9.139 808

Manufacturer

SCAT

Capillary connections

3

SafetyCap II, V2.0 GL45, with shut-off (combined), 2x PFA-fitting 3,2 mm OD + air valve

Manufacturer P/N

307219

Part Number

9.139 899

Manufacturer

SCAT

Capillary connections

2

SafetyCap VI, V2.0, GL45 with 6x shut-off, 6x PFA-fitting 3,2 mm OD + air valve

Manufacturer P/N

307519

Part Number

9.139 804

Manufacturer

SCAT

Capillary connections

6

SafetyCap II, V2.0, GL45 with 2x shut-off, 2x PFA-fitting 3,2 mm OD + air valve

Manufacturer P/N

307919

Part Number

9.139 807

Manufacturer

SCAT

Capillary connections

2

SafetyCap III, V2.0, GL45 with 2x shut-off (combined), 3x PFA-fitting 3,2 mm OD + air valve

Manufacturer P/N

307319

Part Number

9.139 802

Manufacturer

SCAT

Capillary connections

3

Frequently asked questions

It is designed to provide secure and efficient solvent handling in laboratory environments. This cap features four PFA fittings (1.6/2.3/3.2 mm OD), an integrated air valve for pressure equalization, and a labeling field for easy identification. Constructed from durable PTFE, it ensures chemical resistance and compatibility with various solvents. Ideal for use with HPLC systems, it offers enhanced safety and convenience for laboratory operations.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

SG $357.63

Inc. GST