Representative Image

VACUUBRAND Chemical Pumping Unit PC 3016 NT, VARIO® Select 100 to 120 V / 200 to 230 V / 50 to 60 Hz, US Plug 2B350i

Specifications

HS Code #
84141089
Depth
616 mm
Dimensions (WxDxH)
387 x 616 x 450 mm
Flow rate
321.66 l/min
Height
450 mm
Plug type
US
Type
PC 3016 NT VARIO ® select
Ultimate vacuum
70 mbar
Ultimate vacuum with gas ballast
100 mbar
UNSPSC
40151502
Weight
29.7 kg

SG $29,323.72

Inc. GST

Available soon

Product description

The VACUUBRAND Chemical Pumping Unit PC 3016 NT VARIO® select 100-120 V / 200-230 V / 50-60 Hz, US Plug 2B350i is a diaphragm vacuum pump from VACUUBRAND designed for oil-free evacuation and pumping of gases or vapours. The combination of speed controlled VARIO ® chemistry diaphragm pumps and the new VACUU·SELECT vacuum controller makes the VARIO ® select chemistry pumps the ideal solution for chemical processes that require precise vacuum, such as rotary evaporation, vacuum drying or vacuum concentration. Its documented configuration includes electrical supply: 100-120 V, 200-230 V, 50-60 Hz, connection: US Plug, and chemical resistance: High chemical resistance and therefore ideally suited for pumping aggressive gases and vapours.

Key Features:

  • Brand: VACUUBRAND
  • Model: PC 3016 NT
  • Product Type: Diaphragm Vacuum Pump
  • Electrical Supply: 100-120 V, 200-230 V, 50-60 Hz
  • Connection: US Plug
  • Chemical Resistance: High chemical resistance and therefore ideally suited for pumping aggressive gases and vapours
  • Pressure Control: Short process times and smooth running due to optimal setting of the pressure via the VACUU·SELECT controller
  • Vacuum Control: The VARIO ® technology controls the vacuum precisely and efficiently via motor speed
  • Efficiency and Noise: Power consumption, maintenance and noise are exceptionally low
  • Solvent Recovery: The outlet catchpot and solvent condenser combine to prevent solvent vapor emissions into the lab, allowing for nearly full recovery of solvents
  • Power Cord Options: Country-specific power cord versions available on request

The VACUUBRAND Chemical Pumping Unit PC 3016 NT VARIO® select 100-120 V / 200-230 V / 50-60 Hz, US Plug 2B350i supports oil-free evacuation and pumping of gases or vapours where the stated configuration is required. Confirm process compatibility, wetted materials, electrical supply, connections, and included components before ordering.

Accessories

Vacuum tubings, PVC

ProductMaterialExt. ØMfr#Part#AvailabilityPrice
PVC15.9 mm206860604.714 081SG $187.15
PVC34.9 mm206860634.714 084SG $383.57
PVC38.1 mm206860654.714 085SG $446.57
PVC15.9 mm206860614.714 082SG $216.80
PVC22.3 mm206860624.714 083SG $237.18

More items to explore

Chemistry Pumping Unit PC 3001 VARIO® select with condenser Peltronic®

ProductTypeDepthMfr#Part#AvailabilityPrice
PC 3001 VARIO ® select EKP300 mm207002454.669 248SG $20,824.01

Chemistry pumping unit PC 101 NT

Frequently asked questions

It is a diaphragm vacuum pump from VACUUBRAND designed for oil-free evacuation and pumping of gases or vapours. The combination of speed controlled VARIO ® chemistry diaphragm pumps and the new VACUU·SELECT vacuum controller makes the VARIO ® select chemistry pumps the ideal solution for chemical processes that require precise vacuum, such as rotary evaporation, vacuum drying or vacuum concentration.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story