Representative Image

VACUUBRAND Chemistry Pumping Unit PC 101 NT with MZ 2C NT, Certification (NRTL): C/US, 100 to 115 V/50 to 60 V, 120 V/60 Hz, US Mains Cable

Plug type

Specifications

Compare models
HS Code #
84141089
Depth
326 mm
Dimensions (WxDxH)
243 x 326 x 402 mm
Flow rate
2.0 m³/h
Height
402 mm
Plug type
US
Type
PC 101 NT
Ultimate vacuum
7 mbar
Ultimate vacuum with gas ballast
12 mbar
UNSPSC
40151502
Width
243 mm

SG $8,377.41

Inc. GST

Available soon

Product description

The VACUUBRAND Chemistry Pumping Unit PC 101 NT with MZ 2C NT, certification (NRTL): C/US, 100-115 V/50-60 Hz, 120 V/60 Hz, US Mains Cable is a vacuum pumping unit from VACUUBRAND designed for vacuum generation and control for laboratory processes. For evacuation, evaporation and pumping of gases and vapors in chemical, biological and pharmaceutical laboratories. Its documented configuration includes electrical supply: 100-115 V, 50-60 V, 120 V, 60 Hz, connection: US Mains Cable, and certification: NRTL: C/US.

Key Features:

  • Brand: VACUUBRAND
  • Model: PC 101 NT
  • Product Type: Vacuum Pumping Unit
  • Electrical Supply: 100-115 V, 50-60 V, 120 V, 60 Hz
  • Connection: US Mains Cable
  • Certification: NRTL: C/US
  • Chemical and Vapour Resistance: Good chemical resistance and vapor tolerance
  • Vacuum Performance: Good ultimate vacuum even with gas ballast
  • Operation: Oilfree
  • Applications: For evacuation, evaporation and pumping of gases and vapors in chemical, biological and pharmaceutical laboratories
  • Vacuum Regulation: The manual flow control valve regulates the effective pumping speed at the vacuum connection and the vacuum manometer offers an analog vacuum display
  • Solvent Recovery: The waste vapor condenser enables near 100 percent solvent recovery

The VACUUBRAND Chemistry Pumping Unit PC 101 NT with MZ 2C NT, certification (NRTL): C/US, 100-115 V/50-60 Hz, 120 V/60 Hz, US Mains Cable supports vacuum generation and control for laboratory processes where the stated configuration is required. Confirm process compatibility, wetted materials, electrical supply, connections, and included components before ordering.

Accessories

Vacuum tubings, PVC

ProductMaterialExt. ØMfr#Part#AvailabilityPrice
PVC15.9 mm206860604.714 081SG $187.15
PVC34.9 mm206860634.714 084SG $383.57
PVC38.1 mm206860654.714 085SG $446.57
PVC15.9 mm206860614.714 082SG $216.80
PVC22.3 mm206860624.714 083SG $237.18

Compare similar models

Chemistry pumping unit PC 101 NT with MZ 2C NT, certification (NRTL): C/US, 100-115 V/50-60 V, 120 V/60 Hz, US mains cable

Manufacturer P/N

20733003

Part Number

4.670 453

Manufacturer

VACUUBRAND​

Plug type

US

Chemistry vacuum pump stand PC 101 NT with display, controller/cutter and emission condenser

Manufacturer P/N

20733000

Part Number

6.701 344

Manufacturer

VACUUBRAND​

Plug type

EU

Chemistry pumping unit PC 101 NT with MZ 2C NT, certification (NRTL): C/US, 230 V/50-60 Hz, UK/IN mains cable

Manufacturer P/N

20733002

Part Number

4.670 452

Manufacturer

VACUUBRAND​

Plug type

UK

More items to explore

Chemistry pumping units VARIO® select PC 3016 NT

ProductPlug typeTypeMfr#Part#AvailabilityPrice
USPC 3016 NT VARIO ® select257418534.701 144SG $29,323.72

Chemistry Pumping Unit PC 3001 VARIO® select with condenser Peltronic®

ProductTypeDepthMfr#Part#AvailabilityPrice
PC 3001 VARIO ® select EKP300 mm207002454.669 248SG $20,824.01

Frequently asked questions

It is a vacuum pumping unit from VACUUBRAND designed for vacuum generation and control for laboratory processes. For evacuation, evaporation and pumping of gases and vapors in chemical, biological and pharmaceutical laboratories.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story