Representative Image

DOSTMANN PDF Data Logger LOG200 E with Display for Internal Temperature, 1x Input for External Temperature

Brand:Dostmann

Specifications

HS Code #
90259000
Depth
91.5 mm
Dimensions (WxDxH)
42 x 91.5 x 20 mm
Disposable
No
Height
20 mm
Material housing
ABS
Max. measuring cycle
15 min
Max. temp. (external)
850 °C
Max. temperature
70 °C
Measuring cycle
15 min
Min. temp. (external)
-200 °C

SG $264.98

Inc. GST

Available soon

Product description

The DOSTMANN PDF Data Logger LOG200 E is designed for accurate temperature monitoring, featuring a display for internal temperature and inputs for one external Pt 100 temperature sensor. Equipped with a motion sensor for shock recording and an integrated USB interface for automatic PDF output, this versatile data logger is ideal for laboratories, industrial environments, and sensitive transport applications. It offers a freely adjustable recording interval from 10 seconds to 24 hours, min and max values resettable on the display, and a time marking function ("Time Marker") during data recording. The device can be used without additional software or driver installation, and features status and alarm LEDs with buzzer alerts. Battery life extends up to 4 years at recording intervals greater than 15 minutes.

Key Features:

  • Brand: DOSTMANN
  • Display: Integrated display for real-time monitoring of internal temperature with min/max value reset
  • Inputs: 1x input for external Pt 100 temperature sensor for flexible measurements
  • Motion Sensor: Detects shocks and movement during recording
  • Recording Interval: Freely adjustable from 10 seconds to 24 hours
  • Data Output: Automatic PDF file generation via USB; no software or driver installation needed
  • Memory Capacity: Stores up to 100,000 readings
  • Alarm System: Status and alarm LEDs with buzzer
  • Power: Battery life up to 4 years at intervals >15 minutes
  • Can Be Switched: Can be switched off to save power
  • Software: Free software available for download on the manufacturer’s website
  • Applications: Ideal for monitoring temperature in laboratories, industrial environments, and sensitive transport

Scope of Supply:

  • Data logger
  • Wall mount
  • Battery (1/2 AA, 3.6 V)
  • USB cover
  • Screws and dowels

Temperature probes are available as accessories.

The DOSTMANN PDF Data Logger LOG200 E provides a comprehensive solution for temperature monitoring with dual input capability, making it an essential tool for various temperature-sensitive applications.

Frequently asked questions

It is designed for accurate temperature monitoring, featuring a display for internal temperature and inputs for one external Pt 100 temperature sensor. Equipped with a motion sensor for shock recording and an integrated USB interface for automatic PDF output, this versatile data logger is ideal for laboratories, industrial environments, and sensitive transport applications. It offers a freely adjustable recording interval from 10 seconds to 24 hours, min and max values resettable on the display, and a time marking function ("Time Marker") during data recording. The device can be used without additional software or driver installation, and features status and alarm LEDs with buzzer alerts. Battery life extends up to 4 years at recording intervals greater than 15 minutes.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story