Representative Image

OHAUS Centrifuge Micro FC5513+R02 IVD, 230 V

Brand:OHAUS

Specifications

HS Code #
84211920
Depth
356 mm
Dimensions (WxDxH)
277 x 356 x 236 mm
Power supply frequency
50/60 Hz
Height
236 mm
Max. permitted ambient temp.
35 °C
Max. rcf
17317 x g
Max. relative humidity rate
80 %
Max. speed
13500 1/min
Max. voltage
230 VA
Min. permitted ambient temperature
5 °C

SG $3,476.23

Inc. GST

Available soon

Product description

The Ohaus Centrifuge Micro FC5513+R02 IVD, 230V is designed for laboratory sample separation and centrifugation. Microcentrifuge with angle rotor 24 x 1.5/2.0 ml BIOSEALS.

Key Features:

  • Brand: Ohaus
  • Product Type: Centrifuge Micro
  • Model: FC5513+R02 IVD
  • Capacity: 1.5/2.0 ml
  • Voltage: 230V
  • Application: laboratory sample separation and centrifugation

This Ohaus Centrifuge Micro is suitable for users needing reliable performance for laboratory sample separation and centrifugation.

More items to explore

Microcentrifuge Frontier™ FC5513 IVD / FC5513R IVD, without rotor

ProductTypeRated capacityMfr#Part#AvailabilityPrice
FC5513 IVD170 W830415714.713 506SG $3,183.45
FC5513R IVD320 W830415784.713 510SG $8,127.26

Microcentrifuge Frontier™ FC5513 IVD with angle rotor R06

ProductRated capacityMin. permitted ambient temperatureMfr#Part#AvailabilityPrice
120 W5 °C830415804.713 511SG $3,088.95

Frequently asked questions

The FC5513+R02 IVD is designed for laboratory sample separation and centrifugation. This centrifuge micro format supports routine laboratory work in that application.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story