Representative Image

SCAT SafetyCap I, V2.0, GL45 with 1x PFA-fitting

Brand:SCAT

Capillary connections

No. of fittings

Specifications

Compare models
Capillary connections
1
Material
PPS/PTFE
No. of fittings
1 x 1,6/ 2,3/ 3,2 mm
Thread
GL 45
UNSPSC
41115700

SG $370.60

Inc. GST

Available soon

Product description

The SCAT SafetyCap I, V2.0, GL45 is designed to provide secure and efficient solvent supply in laboratory environments. This cap features a single PFA fitting compatible with 1.6 mm, 2.3 mm, and 3.2 mm outer diameter tubing, ensuring versatile connectivity for various laboratory setups. Constructed from high-quality PPS/PTFE materials, it offers exceptional chemical resistance, making it suitable for handling aggressive solvents. The cap includes an integrated air valve for pressure equalization, maintaining system integrity during solvent withdrawal. Additionally, it features a change indicator to monitor filter saturation, enhancing laboratory safety and efficiency.

Key Features:

  • Brand: SCAT
  • Thread Size: GL45
  • Material: PPS/PTFE for high chemical resistance
  • Fittings: 1x PFA fitting for 1.6 mm, 2.3 mm, and 3.2 mm OD tubing
  • Integrated Components: Air valve and change indicator
  • Application: Suitable for solvent supply in HPLC and analytical laboratories

Scope of Supply:

  • Safety Cap
  • Air valve
  • Change indicator
  • PFA fittings
  • PFA blind plug
  • Labelling field

This SCAT SafetyCap I ensures safe and efficient solvent handling, contributing to a secure and compliant laboratory workflow.

Accessories

Thread adapters for SafetyCaps / SafetyWasteCaps, female / male thread

ProductMaterialColourMfr#Part#AvailabilityPrice
PPColourless1070994.005 483In stockSG $198.27
PTFEWhite1079929.139 882SG $201.98
PTFEWhite1079919.139 883SG $201.98
PTFEWhite1079934.005 639SG $201.98
PPColourless1079954.005 641SG $198.27
PPColourless1079964.005 642SG $198.27
PPColourless1079944.005 640SG $198.27
PPColourless1070934.005 477SG $198.27
PPColourless1070794.005 463SG $279.80
PPColourless1070904.005 474SG $198.27
PPColourless1070284.005 433SG $198.27
PTFEWhite1170304.005 789SG $201.98
PPColourless1070954.005 479SG $198.27
PPColourless1070924.005 476SG $198.27
PTFEWhite1070724.005 456SG $279.80
PPColourless1070944.005 478SG $118.59
PPColourless1070864.005 470SG $198.27
PPColourless1070974.005 481SG $201.98
PPColourless1070744.005 458SG $218.65
PPColourless1070854.005 469SG $198.27
PPColourless1070894.005 473SG $198.27
PPColourless1070914.005 475SG $157.50
PPColourless1070964.005 480SG $198.27
PPColourless1070714.005 950SG $198.27
PPColourless1070844.005 468SG $201.98

Air valves Generation 2.0 for SafetyCaps

ProductColourShelf lifeMfr#Part#AvailabilityPrice
Red6 months3170104.669 375In stockSG $100.06
Red6 months3970504.669 377In stockSG $2,318.10
Red6 months3970104.669 376In stockSG $537.37
Red6 months3970086.318 227In stockSG $453.98
Red6 months3971004.683 899In stockSG $3,246.46

Compare similar models

SafetyCap I, V2.0, GL45, 1x PFA-fitting
Available soon
SCAT SafetyCap I, V2.0, GL45 with 1x PFA-fitting

SG $370.60

Inc. GST

Manufacturer P/N

399019

Part Number

4.681 069

Manufacturer

SCAT

Capillary connections

1

SafetyCap II, V2.0, GL45 2x PFA-fitting 3.2 OD, 90° angled + ventilation valve

Manufacturer P/N

399909

Part Number

4.681 070

Manufacturer

SCAT

Capillary connections

2

Frequently asked questions

It is designed to provide secure and efficient solvent supply in laboratory environments. This cap features a single PFA fitting compatible with 1.6 mm, 2.3 mm, and 3.2 mm outer diameter tubing, ensuring versatile connectivity for various laboratory setups. Constructed from high-quality PPS/PTFE materials, it offers exceptional chemical resistance, making it suitable for handling aggressive solvents. The cap includes an integrated air valve for pressure equalization, maintaining system integrity during solvent withdrawal. Additionally, it features a change indicator to monitor filter saturation, enhancing laboratory safety and efficiency.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

SG $370.60

Inc. GST

SCAT SafetyCap I, V2.0, GL45 with 1x PFA-fitting | LabFriend Singapore