Representative Image

Bohlender b.safe Table Distributor, PP/PFA for 8x UNF1/4", 5x NPT1/8" Fastening with Adhesive Pad

Brand:Bohlender

Capillary connections

Hose connections

No. of blind plugs

No. of fittings

No. of olives

Specifications

Compare models
HS Code #
39269097
Capillary connections
8
Hose connections
5
Material
PP
No. of blind plugs
12
No. of fittings
8 x 1,6/2,2/3,2 mm
No. of olives
4 x 6 ... 8 mm, 90°, 1 x 6 ... 8 mm
UNSPSC
41115700

SG $361.34

Inc. GST

Available soon

Product description

The Bohlender b.safe Table Distributor, PP/PFA for 8x UNF1/4", 5x NPT1/8" with adhesive pad fastening, is engineered for secure and efficient fluid distribution in laboratory setups. Designed specifically for central waste collection from several HPLC systems, it enables kink-free connection of capillaries and tubes using the included fittings. The vertical hole inside the distributor ensures direct, residue-free solvent waste flow, maintaining a clean and safe laboratory environment. Constructed from high-quality PP/PFA, this distributor offers excellent chemical resistance and durability. The silicone-free adhesive pad allows for easy and stable installation on worktables.

Key Features:

  • Brand: Bohlender
  • Material: PP/PFA for excellent chemical resistance and durability
  • Design: 8x UNF1/4" and 5x NPT1/8" connections for versatile fluid distribution
  • Fastening: Silicone-free adhesive pad for easy and secure attachment
  • Application: Ideal for laboratory fluid distribution and central solvent waste collection systems

Scope of Supply:

  • Table distributor body
  • Fittings with UNF 1/4" threads
  • Tube connectors with NPT 1/8" threads
  • Silicone-free adhesive pad for installation

This table distributor provides laboratories with a reliable, efficient, and chemically robust solution for fluid distribution and solvent waste management.

Compare similar models

b.safe Table distributor, PP/PFA for 8x UNF1/4", 5x NPT1/8" fastening with adhesive pad

Manufacturer P/N

R 1123-04

Part Number

6.491 989

Manufacturer

Bohlender

Capillary connections

8

b.safe Table distributor, PP/PFA for 4x UNF1/4", 3x NPT1/8" fastening with adhesive pad

Manufacturer P/N

R 1123-02

Part Number

6.491 988

Manufacturer

Bohlender

Capillary connections

4

More items to explore

Table distributor b.safe, PP, with magnet

ProductMaterialCapillary connectionsMfr#Part#AvailabilityPrice
PP4R 1122-026.491 986SG $302.04
PP8R 1122-046.491 987SG $522.55

Frequently asked questions

It is engineered for secure and efficient fluid distribution in laboratory setups. Designed specifically for central waste collection from several HPLC systems, it enables kink-free connection of capillaries and tubes using the included fittings. The vertical hole inside the distributor ensures direct, residue-free solvent waste flow, maintaining a clean and safe laboratory environment. Constructed from high-quality PP/PFA, this distributor offers excellent chemical resistance and durability. The silicone-free adhesive pad allows for easy and stable installation on worktables.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story
Bohlender b.safe Table Distributor, PP/PFA for 8x UNF1/4", 5x NPT1/8" Fastening with Adhesive Pad | LabFriend Singapore