Representative Image

Bohlender HT Laboratory Screw Joint GL 14 Ø 2.0 mm, SW 17, PPS

Brand:Bohlender

For ext. tubing Ø

Specifications

Compare models
HS Code #
39269097
Colour
Black
For ext. tubing Ø
2.00 mm
Material
PPS
Thread
GL 14
UNSPSC
41121815

Alternative in-stock items

SG $100.06

Inc. GST

Available soon

Product description

The Bohlender HT Laboratory Screw Joint GL 14 Ø 2.0 mm, SW 17, PPS is designed for secure and reliable connections in laboratory setups. Featuring a black screw cap made of PPS and inner components comprising a clamping ring (PPS), sealing wedge, and sealing plate (both PTFE), along with an additional O-ring (FKM), this screw joint ensures excellent chemical resistance and durability. The medium contacts only PTFE, making it suitable for sensitive applications. It is temperature resistant from -50°C to +250°C, pressure stable up to 10 bar, and vacuum compatible, making it ideal for connecting equipment and fittings with GL threads to hard-walled tubing made of glass, plastic, or metal.

Key Features:

  • Brand: Bohlender
  • Thread Size: GL 14
  • For Tubing Ø: 2.0 mm
  • Wrench Size (SW): 17
  • Material: PPS cap with PTFE inner components
  • Temperature Resistance: -50°C to +250°C
  • Pressure Stability: Up to 10 bar
  • Vacuum Compatibility: Yes

This screw joint is essential for laboratories requiring high-performance connections with excellent chemical resistance and thermal stability.

Downloads

Compare similar models

HT Laboratory Screw Joint GL 14 Ø 2,0 mm, SW 17, PPS

Manufacturer P/N

D 628-34

Part Number

6.307 187

Manufacturer

Bohlender

For ext. tubing Ø

2.00 mm

HT Laboratory Screw Joint GL 14 Ø 6,0 mm, SW 17, PPS

Manufacturer P/N

D 628-74

Part Number

6.900 068

Manufacturer

Bohlender

For ext. tubing Ø

6.00 mm

HT Laboratory Screw Joint GL 14 Ø 1,0 mm, SW 17, PPS

Manufacturer P/N

D 628-18

Part Number

6.901 758

Manufacturer

Bohlender

For ext. tubing Ø

1.00 mm

HT Laboratory Screw Joint GL 14 Ø 3,0 mm, SW 17, PPS

Manufacturer P/N

D 628-50

Part Number

6.304 933

Manufacturer

Bohlender

For ext. tubing Ø

3.00 mm

HT Laboratory Screw Joint GL 14 Ø 4,0 mm, SW 17, PPS

Manufacturer P/N

D 628-66

Part Number

7.601 156

Manufacturer

Bohlender

For ext. tubing Ø

4.00 mm

HT Laboratory Screw Joint GL 14 Ø 1,6 mm, SW 17, PPS

Manufacturer P/N

D 628-26

Part Number

6.307 933

Manufacturer

Bohlender

For ext. tubing Ø

1.60 mm

HT Laboratory Screw Joint GL 14 Ø 3,2 mm, SW 17, PPS

Manufacturer P/N

D 628-58

Part Number

6.303 128

Manufacturer

Bohlender

For ext. tubing Ø

3.20 mm

HT Laboratory Screw Joint GL 14 Ø 6,35 mm, SW 17, PPS

Manufacturer P/N

D 628-78

Part Number

7.603 089

Manufacturer

Bohlender

For ext. tubing Ø

6.35 mm

HT Laboratory Screw Joint GL 14 Ø 8,0 mm, SW 17, PPS

Manufacturer P/N

D 628-82

Part Number

6.084 147

Manufacturer

Bohlender

For ext. tubing Ø

8.00 mm

Laboratory screw joints GL 14 Ø 5,0 mm, SW 17, PPS

Manufacturer P/N

D 628-70

Part Number

6.237 145

Manufacturer

Bohlender

For ext. tubing Ø

5.00 mm

Frequently asked questions

It is designed for secure and reliable connections in laboratory setups. Featuring a black screw cap made of PPS and inner components comprising a clamping ring (PPS), sealing wedge, and sealing plate (both PTFE), along with an additional O-ring (FKM), this screw joint ensures excellent chemical resistance and durability. The medium contacts only PTFE, making it suitable for sensitive applications. It is temperature resistant from -50°C to +250°C, pressure stable up to 10 bar, and vacuum compatible, making it ideal for connecting equipment and fittings with GL threads to hard-walled tubing made of glass, plastic, or metal.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story