Representative Image

Grant Instruments JB Nova General Purpose Water Bath JBN12, Digital, 12 L, AMB5, 20°C to 95°C, Includes Clear Lid and Base Tray

Brand:Grant

Capacity

Depth int.

Ext. dim. (WxDxH)

Ext. depth

Ext. height

Ext. width

Heating capacity

Height int.

Int. Dim. (WxDxH)

Int. width

Temperature

Type

Weight

With stopcock

Specifications

Compare models
HS Code #
84198998
Capacity
12 l
Depth int.
281 mm
Ext. dim. (WxDxH)
360 x 380 x 225 mm
Ext. depth
380 mm
Ext. height
225 mm
Ext. width
360 mm
Heating capacity
800 W
Height int.
132 mm
Int. Dim. (WxDxH)
308 x 281 x 132 mm
Int. width
308 mm

SG $2,158.74

Inc. GST

Supplier Stock: 2
Estimated shipping time from Germany : 4-6 weeks

Product description

The Grant Instruments JB Nova General Purpose Water Bath JBN12 is a highly versatile and efficient heating solution for laboratory applications. With a 12-liter capacity and a temperature range of 20°C to 95°C, this digital water bath ensures accurate and uniform heating for sample preparation, incubation, and other laboratory procedures. The unit includes a clear lid and base tray, offering enhanced functionality and visibility. Ideal for biological, chemical, and clinical laboratories, the JBN12 delivers consistent, reliable results in a range of applications.

Key Features:

  • Brand: Grant Instruments
  • Model: JBN12, General Purpose Water Bath
  • Capacity: 12 L
  • Temperature Range: 20°C to 95°C, ideal for versatile laboratory applications
  • Display: Digital display for precise temperature control
  • Inclusions: Clear lid and base tray for better sample visibility and convenient use
  • Application: Perfect for sample heating, incubation, and maintaining precise temperatures in labs

This Grant Instruments JB Nova General Purpose Water Bath JBN12 is the ideal solution for laboratories requiring consistent and reliable temperature control for large-volume sample processing.

Downloads

Accessories

LLG-Floating pellets, PP

ProductDescriptionMaterialMfr#Part#AvailabilityPrice
LLG-Floating pelletsPP62666116.266 611In stockSG $126.00

Lids LU for Grant water baths, stainless steel

ProductTypeType of lidMfr#Part#AvailabilityPrice
LU14Gable coverLU149.905 771SG $594.81
LU6Gable coverLU69.905 770SG $541.08
LU36Gable coverLU369.905 773SG $770.85
LU28Gable coverLU289.905 772SG $667.08
LS200Gable coverLS2009.905 809SG $704.14

Compare similar models

Water bath JB NOVA GENERAL PURPOSE JBN12 digital, 12 L, amb.+5 to 95°C, includes clear lid and base tray

Manufacturer P/N

JBN12

Part Number

9.905 871

Manufacturer

Grant

Capacity

12 l

Water bath JB NOVA GENERAL PURPOSE JBN5 digital, 5 L, amb.+5 to 95°C, includes clear lid and base tray

Manufacturer P/N

JBN5

Part Number

9.905 870

Manufacturer

Grant

Capacity

5 l

Water bath JB NOVA GENERAL PURPOSE JBN18 digital, 18 L, amb.+5 to 95°C, includes clear lid and base tray

Manufacturer P/N

JBN18

Part Number

9.905 872

Manufacturer

Grant

Capacity

18 l

Water bath JB NOVA GENERAL PURPOSE JBN26 digital, 26 L, amb.+5 to 95°C, includes clear lid and base tray

Manufacturer P/N

JBN26

Part Number

9.905 873

Manufacturer

Grant

Capacity

26 l

Frequently asked questions

It is a highly versatile and efficient heating solution for laboratory applications. With a 12-liter capacity and a temperature range of 20°C to 95°C, this digital water bath ensures accurate and uniform heating for sample preparation, incubation, and other laboratory procedures. The unit includes a clear lid and base tray, offering enhanced functionality and visibility. Ideal for biological, chemical, and clinical laboratories, the JBN12 delivers consistent, reliable results in a range of applications.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story