Sartorius Vivaflow 50R, 5.000 MWCO Hydrosart Membrane

Brand:Sartorius

MWCO

Specifications

Compare models
HS Code #
84212980
Material membrane
Hydrosart®
Membrane surface
50 cm²
MWCO
5000 da
UNSPSC
41104916

SG $787.52

Inc. GST

Available soon

Product description

The Sartorius Vivaflow 50R, featuring a 5.000 MWCO Hydrosart Membrane, is designed for high-performance filtration in laboratory applications. With its unique Hydrosart membrane technology, this product ensures reliable separation and filtration of proteins, particles, and other biomolecules with excellent retention properties. Ideal for protein purification, concentration, and other critical filtration processes, the Vivaflow 50R is a versatile and efficient tool for laboratory research.

Key Features:

  • Brand: Sartorius
  • Model: Vivaflow 50R
  • Membrane: Hydrosart with 5.000 MWCO
  • Application: Ideal for protein purification, concentration, and filtration tasks
  • Technology: Hydrosart membrane for high performance and reliability
  • Filter Area: 50 cm² for optimal throughput
  • Volume Capacity: Suitable for 100–1000 ml samples
  • Performance: Concentrates 250 ml by a factor of 20 in under 30 minutes
  • Scalability: Two cassettes can be run simultaneously to concentrate 1000 ml in about 45 minutes
  • Reusability: Designed for repeated use with high flow rate and recovery
  • Packaging: Supplied individually

Scope of Supply

  • Crossflow filter units
  • Tubing
  • Pressure indicator
  • Flow restrictor

The Sartorius Vivaflow 50R with 5.000 MWCO Hydrosart membrane delivers efficient, reusable, and scalable filtration performance, providing laboratories with a dependable solution for biomolecule concentration and purification workflows.

Downloads

Accessories

Flow restrictor set

ProductDescriptionUNSPSCMfr#Part#AvailabilityPrice
Flow restrictor set41123100VF-AC-0002-V4.713 207SG $51.88

Tubing kits for crossflow filter units Vivaflow® 50R/200

ProductDescriptionUNSPSCMfr#Part#AvailabilityPrice
Tubing kit for running two 50R cassettes in parallel41123100VF-ATP0011-14.713 211SG $339.10
Tubing kit for running two 200 cassettes in parallel41123100VF-ATP0012-14.713 212SG $339.10
Tubing kit for running a single cassette41123100VF-ATI0011-14.713 210SG $279.80

Compare similar models

Vivaflow® 50R, 5.000 MWCO Hydrosart Membrane
Available soon
Sartorius Vivaflow 50R, 5.000 MWCO Hydrosart Membrane

SG $787.52

Inc. GST

Manufacturer P/N

VF05H1

Part Number

6.319 438

Manufacturer

Sartorius

MWCO

5000 da

Vivaflow® 50R, 10.000 MWCO Hydrosart Membrane, 100-1000ml
Available soon
Sartorius VIVAFLOW 50R 10,000 MWCO Hydrosart 100-1000ml

SG $787.52

Inc. GST

Manufacturer P/N

VF05H0

Part Number

6.490 315

Manufacturer

Sartorius

MWCO

10000 da

Vivaflow® 50R, 30.000 MWCO Hydrosart Membrane
Available soon
Sartorius Vivaflow 50R, 30,000 MWCO Hydrosart Membrane

SG $787.52

Inc. GST

Manufacturer P/N

VF05H2

Part Number

6.311 629

Manufacturer

Sartorius

MWCO

30000 da

Vivaflow® 50R, 100.000 MWCO Hydrosart Membrane
Available soon
Sartorius Vivaflow 50R, 100,000 MWCO Hydrosart Membrane

SG $787.52

Inc. GST

Manufacturer P/N

VF05H4

Part Number

4.666 017

Manufacturer

Sartorius

MWCO

100000 da

Frequently asked questions

It is designed for high-performance filtration in laboratory applications. With its unique Hydrosart membrane technology, this product ensures reliable separation and filtration of proteins, particles, and other biomolecules with excellent retention properties. Ideal for protein purification, concentration, and other critical filtration processes, the Vivaflow 50R is a versatile and efficient tool for laboratory research.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story