Representative Image

Thistle Scientific MultiSub Midi96 Stretch UV Tray Comb Block (12×8 Samples, 1mm, with Casting Dams, Two Marker Lanes)

Depth gel

Depth

Dimensions (WxDxH)

Gel (WxD)

Height

Nominal capacity

Type

Specifications

Compare models
HS Code #
90272000
Depth gel
240 mm
Depth
465 mm
Dimensions (WxDxH)
125 x 465 x 80 mm
Gel (WxD)
100 x 240 mm
Height
80 mm
Max. number of samples
96
Nominal capacity
700 ml
Type
MultiSUB Midi-96 ST/2M
UNSPSC
41105340
Width gel
100 mm

SG $1,295.25

Inc. GST

Available soon

Product description

The Thistle Scientific MultiSub Midi96 Stretch UV Tray Comb Block is designed for high-throughput electrophoresis, offering a UV-permeable stretchable tray for clear and effective gel visualization. This 12×8 well format supports up to 96 samples and features 1mm thick combs for precise and uniform well formation. The tray includes two marker lanes for easier sample tracking, and casting dams are included for efficient gel casting. Ideal for applications such as genotyping, PCR screening, and protein analysis in molecular biology labs.

Key Features:

  • Brand: Thistle Scientific
  • Tray Size: 12×8 well format supporting up to 96 samples
  • Tray Type: UV-stretchable tray for excellent gel visibility
  • Comb Size: 1mm thick combs for precise well formation
  • Marker Lanes: Includes two marker lanes for easier tracking of sample migration
  • Casting Dams: Included for clean, efficient gel casting
  • Application: Ideal for high-throughput DNA/RNA electrophoresis and protein analysis

This MultiSub Midi96 Stretch system is the perfect solution for labs requiring flexibility, precision, and high sample capacity in their electrophoresis applications.

Accessories

Combs MC for Gel Electrophoresis Tank MultiSUB Midi-96

ProductFits forNo. of markersMfr#Part#AvailabilityPrice
MultiSUB Midi-962MSMIDI96-8-1/2M-9.584 722SG $402.10
MultiSUB Midi-962MSMIDI96-8-1.5/29.584 723SG $402.10
MultiSUB Midi-96ST1MSMIDI96ST-8-1.59.584 725SG $594.81
MultiSUB Midi-961MSMIDI96-8-1.5-C9.584 721SG $402.10
MultiSUB Midi-96ST2MSMIDI96ST-8-1/29.584 726SG $594.81
MultiSUB Midi-96ST2MSMIDI96ST-8-1.59.584 727SG $594.81

Power supply nanoPAC-300 Mini for gel electrophoresis tanks

ProductTypeType of auxiliary energyMfr#Part#AvailabilityPrice
nanoPAC-300P MiniMains connectionNANOPAC-300P6.272 711SG $1,095.12

Compare similar models

multiSUB Midi96 STRETCH UV-tray, comb block with 12x8 samples 1 mm, casting dams, combs have two marker lanes

Manufacturer P/N

MSMIDI96ST/2M

Part Number

6.270 481

Manufacturer

Thistle Scientific

Depth gel

240 mm

multiSUB midi UV-tray, 12 combs with each 8 samples, casting damps

Manufacturer P/N

MSMIDI96/2M

Part Number

6.242 108

Manufacturer

Thistle Scientific

Depth gel

120 mm

Frequently asked questions

It is designed for high-throughput electrophoresis, offering a UV-permeable stretchable tray for clear and effective gel visualization. This 12×8 well format supports up to 96 samples and features 1mm thick combs for precise and uniform well formation. The tray includes two marker lanes for easier sample tracking, and casting dams are included for efficient gel casting. Ideal for applications such as genotyping, PCR screening, and protein analysis in molecular biology labs.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story